MV&HV Low Attenuation Transmission Cable

  • 特种电缆.jpeg

1.Standard: 

   Company Standard

2.Application

  For High-power electricity transmission, electromagnetic, laser accelerator DC high voltage system and electrical control device transmission and          connection cables, with good characteristics of high load, solar ageing resistance. It has the ability of resisting working pulse current and short circuit    fault current, and can meet the data index of inductance and capacitance.

3. Operating Performances:

   1). Conductor DC resistance at 20℃ meets standard of circle copper conductor as per GB/T 3956 class5.

   2).The long-term allowed continuous operating temperature is 90℃;

   the outdoor ambient temperature is -20~+70℃;

   the minimum allowed bending radius is 10D(D: diameter of cable).

   3).Finished cables can bear 50Hz DC;

   The Voltage Test between inner & outer cores:

DC Withstand Voltage

Voltage Test between inner &   outer cores

20 kV.DC

30 kV.DC×3min without breakdown

50 kV.DC

60 kV.DC×3min without breakdown

80 kV.DC

100 kV.DC×3min without breakdown

4. Type / Model/ Range:

Type

Model

Range(core×cross section )( mm2)

HEPV

MV&HV Low Attenuation Transmission Cable

1×14~1×185

5. Remarks: MV&HV Low Attenuation Transmission Cable with Special Structure & Larger Cross-section is available for customizing.