· 1. Standard: GB/T 12528-2008
· 2. Application: 3kV & below AC rated voltage electrical devices (power distribution system, control system, and signal system etc.) cable for rail transit vehicles.
· 3. Operating performance:
· 1). AC rated voltage of cables: 750V、1500V、3000V
· 2). Maximum conductor temperature for continuous operation: 125℃,
· Minimum laying temperature: -40℃
· 3). Fit for operation under pollution of mineral oil & fuel oil
· 4). Allowed bending radius for laying:
· ≥6D ( D≤20mm)
· ≥8D (D>20mm)
· 5). a. Finished cable has fireproofing characteristics of single wire/cable; in line with GB/T 18380.1-2001.
· b. Finished cable has fireproofing characteristics in bunch of wires/cables; in line with GB/T 18380.3-2001 or IEC60332-3-25:2000.
· c. LSOH in line with GB/T 17651.2-1998 & GB/T 17650.2-1998.
· 4.Type / Voltage / Range / Standard
Type | Rated Voltage (V) | Nominal Cross (mm2) | Standard |
WDZ-DCYJ-125 WDZ-DCYJ/2-125 WDZ-DCYJ/3-125 | 750 | 0.75-300 | GB/T 12528-2008 |
1500 | 0.75-300 | ||
3000 | 0.75-300 |
· 5.Special Customizing is available as per customer’s special requirements.